Description
GRR Robust Radiator Diameter 2″ Length 4″. This is the coil length and ID. At least 0.5″ extension on each side beyond coil length. Power 2.5 KW@ 240 Volts plug-in.
• Optional Tube with two end caps may be placed in the Robust Radiator. The tube will be mullite, and the end caps will be metal.
• Tube will protrude at least 1″ beyond the RR face. The tube is optional – supplied with end caps. Note ceramic plugs to limit heat loss (option CEC) but with the ability to maintain flow are also offered as options. These are recommended.
• Please note that the power available from the RR for heating is lower when a tube is placed in it
• The internal temperature in the tube will depend on the load in the tube
(Picture shows optional tube and SS shell). These have to be purchased in the pull-down menu.
The GRR will plug into a 208 – 240V single-phase supply. The control panel is optional but highly recommended. However, if not purchased, the user should monitor the temperature not to exceed 1200°C during use.
The control Panel BPAN-O-PLUS when purchased, can be supplied in a UL or cUL rating. This control panel has an SCR, soft start, and two readouts (one for process temperature and one for the over-temperature function).