Airtorch® Models MVTA, GTA925 and MTA925 up to 1200°C.

Stay on this page for units less than 15 KW.   Click here for larger power units.

Flanged heaters up to 1200°C.

Fan and blower VTA Airtorch® Models to 1100°C (2012 °F) – see below.

GTA

LTA, VTA, MTA, DPF, DPF-DNA and MVTA models are not pressure rated but could be sealed depending on the model.  Only the models begining with a G like the GTA models are pressure rated to the appropriate pressure.

Return to Airtorch® Home. Process Air and Process Gas Heaters.

Request Quote for Airtorch™

Flanged Sealed Process Heaters  to 1200°C Air/Gas 

Guide for Airtorch® Selections Request Quote for Airtorch™

Temperature Lower Power (1-12 kW) High Power (36-600 kW)
600-1000°C LTA, VTA, MTA925 MVTA-900-(DNA) Models SH
900-1100°C MVTA-900-(DNA) Models MVTA-1000-(DNA) Models, SH

MVTA-DPF(DNA) Models

1200°C/1300°C DPF Models

V-DPF, DPF and GDPF

MVTA-DPF(DNA) Models

GDPF(DNA) Models

High Pressure Enclosures (GTA, GVTA) Up to 1200°C

Please see tables below for individual models

Features and Applications

  • Robust Design
  • Clean and Green product with high energy efficiency
  • DF (Direct-Flow).  Low resistance. Low pressure drop.
  • Automotive Applications
  • Service Plan (No Downtime)
  • Solid Oxide Fuel Cells
  • 2kW to 600kW Models.
  • Integration Technology
  • Installation Services Provided
  • Special Application with Low Cost Blowers and High CFM
  • Energy Efficient
  • In-Line Configuration
  • Maximum Operating Temperature of MTA925 is 1000°C (1832°F). MVTA models to 1100° (2100°F).
  • Need more power? High watt models.

Convective Heating is One of the Most Versatile Ways of Delivering Heat!

Low Pressure Drop and No Noise

  • Sealed process gas heater inline or with fan or blower capability. Temperature measurements are reported at the integrated thermocouple location supplied with the Airtorch®—lowest pressure drop in SH models.
  • New MVTA-DPF models for 1100°C.
  • GTA or GVTA is also offered – For high-pressure vessel Airtorch® use.
  • Data Acquisition and Electronic Controls are available.
  • Temperature up to 1200°C (click for models).
  • Please choose this model for very low flow high temperature uses such as less than 100 SCLM.
  • Request Quote for Airtorch™

MVTA, VTA-DPF-DNA Models – 1100°C and 1200°C

1-10 KW Single Phase

15KW Single or 3-Phase User Choice

36KW 3 Phase
208-240V 50/60Hz

Model # Power
VTA-DPF-6.5-1100  (DNA) (Fan)

or

choose inline model

MVTA-DPF-6.5- 1100 (DNA)

6.5KW

Single Phase. Fan Controller Included.

or Choose

Inline Flanged Model

MVTA(or GTA)-DPF-15-1100 (DNA)

GTA

15 KW

Both single-phase and 3-phase Models are offered.

MVTA(or GTA)-DPF-(24,36-48-96)-1100 (DNA)

3 Phase

24 KW,36 KW,48 KW,96 KW

3 Phase 240V, 480V, or 400V.  CE and UL-rated electric panels are available.

MTA925 and GTA925 Airtorch® – 925C
Single Phase 208-240V, 50/60Hz

LTA, VTA, MTA, MVTA models are not pressure rated but could be sealed depending on the model.  Only the models beginning with a G like the GTA models are pressure rated to the appropriate pressure.

Request Quote for Airtorch™

Model # Power Picture
MVTA925-12 and GTA925-12-(PV)

(1000°C)

Single Phase Controls

XPAN

12 KW MVTA925-12 Model Process Gss Heater

MVTA925-12 and GTA925-12-(PV)

the GTA925 -12 version is available in single and three phase configurations

GTA925-12-18(PV)

MTA925-02

(950C)

Online Store

2 KW MTA925-2 Thumb

Online Store

GTA925-02-3PV

(950C) RFQ

GTA925-02-6PV

(925C) RFQ

2 KW  3Bar

2 KW 6Bar

RFQ

MTA925-04

(950C) Online Store

4 KW Online Store

MTA925-04

GTA925-04-3PV

(950°C) RFQ

GTA925-04-6PV

(950°C) RFQ

4 KW 3 Bar

4 KW 6 bar

RFQ

Request Quote for Airtorch™

Combustible gases for abatement purposes

To heat combustible gases for abatement purposes such as for semiconductor gas abatement –   MVTA925-GA6125-H2.

MVTA-GA Models for 900°C

Combustible Gasses

ATEX rating Available

Model # Power
MVTA925-GA6125-H2 or MVTA-2(10)-220- H2

(for Combustible Low Flow Process Gas-Heating)

12 kW

or

5 kW

Marks of Quality

Specifications subject to change at the time of quotation.

Fans are employed when the drop in pressure of the system is no greater than approximately 50 in. w.c. (50 in. w.c./inches of H20 is approximately 1.8psi.) This condition remains true even when the fan can output large CFM values.  Blowers are considered in circumstances where larger pressure drops are present.

Flow-Gas Accessories

 Accessories that are currently available for our MTA & MVTA Models

Please contact MHI for GVTA or GTA models

Blower and low flow detection system.
 Accessories
FLM750 – Flowmeter 2-23 SCFM (click for larger images)

Controls.  Single and Three Phase.  From XPAN, TRIPAN, RPAN to I-TRIPAN.

Flow Mixers

SIMGAS (Gas Mixing)

and

FlowGas

Flow meter 2-23 SCFM
Part # FLM750
   

Blower and low Flow detection system. SIMGAS (Gas Mixing)
MVTA Blower control system

Choice of controls (fans/Blowers/Compressed air or gas):

Call 513-772-0404 to discuss or email us.